• Home > BUSINESS > LEVEL > Magnetic Float Type Cargo Tank
◊ Magnetic Float Type Cargo Tank
|
1. Level Detection Part
Type |
Reed switch with
Magnetic Float |
Allowable Temperature |
-60 ~ +120℃ |
Anti-Explosion
Structure |
Intrinsically
safe,
Ex ia II C T6 |
Allowable pressure |
3㎏/㎠
(oprion:80kgf/㎠,max) |
Measuring Range |
200M Max. |
|
Float
(SUS316 or 316L) |
Speciflc Gravity |
0.5 and above
(of liquid in tank) |
Material |
Guide Pipe
(SUS316 or 316L) |
Viscosity |
15,000sec
Redwood No.1 Max |
|
Housing (SUS304) |
Detecting Accuracy |
±20.0mm
(standard) |
|
Lacal indicator housing(SUS304) |
2. Temperature Detection Part
Type |
Two-terminal IC,temp. transducer |
Measuring Range |
-50/+130℃ |
Detecting Accuracy |
±1℃ |
3. Pressure Detection Part
Type |
Diaphragm with strain gauge bridge |
Measuring Range |
-0.4/+25bars |
Detecting Accuracy |
0.5% of F.S |
2. Transducer/Indicator Part
Electric Source |
AC110/220V,60Hz,
back up source:DC24V |
Output |
4~20mA or RS-232C
or RS-422, RS-485 |
Allowable Temperature |
-20/~ +80℃ |
Indicator |
CRT or Indicator Unit Or Digital/Analog Indicator |
|
•
DIMENSION
|